linux系统下一个冷门的RAID卡ioc0及其监控mpt-status

这篇文章主要介绍了linux系统下一个冷门的RAID卡ioc0及其监控mpt-status,需要的朋友可以参考下

新接手了一台Linux服务器,准备检查是否有配置RAID。
 
先查看是否有RAID卡:


# dmesg|grep -i raid
mptsas: ioc0: attaching raid volume, channel 1, id 0
device-mapper: dm-raid45: initialized v0.2594l
md: Autodetecting RAID arrays.

很明显是有的,只是无法确定RAID卡的类型是ioc0还是dm-raid45,于是开始百度。后来找到了这样一个工具:mpt-status,而且在下载界面里,有这样几句话:
 
mpt-status: get status of LSI 1030 RAID (mptlinux, fusion, mpt, ioc) controller
 
This driver has many names. As best I understand their use:
LSI 1030
    The make and model of the controller
mptlinux
    The name of the driver distribution. /proc/mpt/version might say, for example, mptlinux-2.05.11.03.
Fusion
    The trade name for the chipset (?). The driver distribution, though called mptlinux, actually lives in drivers/message/fusion.
mpt
    Message Passing Technology; the prefix used for all things that related to the driver. The /proc device is /proc/mptctl, for example.
ioc
    The name of the controller within Linux. For example the first controller is ioc0.
 
大意是说LSI 1030 RAID卡有很多个名字,ioc是其中之一。这刚好与之前dmesg的结果吻合。因此基本上可以确定RAID卡的类型是ioc0,属于LSI的产品,可以用mpt-status来对其进行监控。

mpt-status下载地址:http://sven.stormbind.net/mpt-status-rhel/
 
接着下载安装:rpm -ihv mpt-status-1.2.0_RC7-3.i386.rpm
 
建立字符设备:mknod /dev/mptctl c 10 220
加载内核模块mptctl:modprobe mptctl
 
查看RAID状态:


# mpt-status       
ioc0 vol_id 0 type IM, 2 phy, 465 GB, state OPTIMAL, flags ENABLED
ioc0 phy 1 scsi_id 8 ATA      WDC WD5002ABYS-1 3B04, 465 GB, state ONLINE, flags NONE
ioc0 phy 0 scsi_id 1 ATA      WDC WD5002ABYS-1 3B04, 465 GB, state ONLINE, flags NONE

可以看出,该RAID由两块465G的物理硬盘组成,状态良好。可问题是,RAID级别是多少(0,1,5...)呢?
 
于是接着百度。
 
但这次没有结果。
 
后来在mpt-status的文档(/usr/share/doc/mpt-status-1.2.0_RC7/FAQ )里看到这样一句话:
 
> 1) Could you tell me from example #1, #2 and #3 where can you see the Raid Level of each hard disk ?
 
好激动,这不就是我要问的问题吗?再看看答案:
 
The raid level is not visible, would you like to get this information as well? Or do you want to extract the health state of each disk?
 
尼玛,回答跟没回答一样...
 
接着往下看。终于,在文档的最后,给出来了答案:
 
> IS=?
Integrated Striping (RAID 0)
> IM=?
Integrated Mirroring (RAID 1)
 
即mpt-status输出的type表示RAID级别。如上例中的:
 
ioc0 vol_id 0 type IM, 2 phy, 465 GB, state OPTIMAL, flags ENABLED
 
表示RAID1。
 
最后附上mpt-status的rpm包。
 
mpt-status 下载地址:http://sven.stormbind.net/mpt-status-rhel/

本站部分内容来源互联网,如果有图片或者内容侵犯您的权益请联系我们删除!

相关文档推荐

RAID技术分为几种不同的等级,分别可以提供不同的速度,安全性和性价比。根据实际情况选择适当的RAID级别可以满足用户对存储系统可用性、性能和容量的要求。
安装程式实现软件RAID代替硬件RAID的方法,今天再进一步谈谈手动创建软RAID和日常维护的方法。
有两台IBM X346 m/t-8840-cdr 服务器,板载raid控制器版本号为v.4.30.9,硬盘位0,1各装一块146G IBM 原装SCSI硬盘。
X服务器中有一些集成LSI SCSI控制器的机型,在开机自检时按CTRL C可以配置两个硬盘的镜像。但是当升级BIOS之后,CTRL C中的一些设置发生了变化,配置方法也较以前的版本有些差异
这篇文章主要是因为最近的服务器为了安全性考虑了做了raid1,但怕硬盘出问题,特整理了这篇文章,并根据自己的经验结合了下,希望能帮到需要的朋友
这篇文章主要介绍了主流的带有RAID功能的升技主板基本的RAID创建过程的介绍,希望能够给对RAID有兴趣的升技主板用户有所帮助